Skip to main content
DM5E - Basic (0036800) Thickness gauge range

DM5E - Basic (0036800) GE Inspection Technologies Italy Sales

If you are looking for a reliable supplier where you can purchase the DM5E - Basic (0036800) Thickness gauge range, you are in the right place. PARTELLI sells in the Italy marketGE Inspection Technologies all product groups belonging to the brand, with fast delivery times and competitive prices.

DM5E - Basic (0036800) Thickness gauge range
ProductDM5E - Basic (0036800)
BrandGE Inspection Technologies
SupplierPARTELLI S.R.L.
CountryItaly
Request a price
Delivery time: Determined at the time of quotation
VISA Mastercard Bank Transfer

Technical Specification

Operating principle Ultrasonic, pulse echo measurement method Measuring range Depends on probe and material, 0.60 mm to 508 mm (0.025” to 20.00”) in IP to 1st BW measurement mode, 2.00 mm to 127.0 mm (0.079” to 5.00”) in dual-multi measurement mode, the coating thickness range shall be 0.3 mm to 2.50 mm (0” to 0.098”). Measuring resolution 0.01 mm default - selectable 0.01, 0.1 mm (0.001” default - selectable 0.001”, 0.01”) Material velocity range 0.508 to 18.699 mm/msec (0.0200” to 0.7362”/msec) Material velocity resolution 1 m/s (0.0001”/msec) Units Inch or millimeter Calibration One-point cal, on-block and off-block, two-point cal Pulser Excitation Pulse Spike pulser Voltage 120 V into 50 ohm load, using 20 MHz oscilloscope Receiver Bandwidth 500 KHz to 12 MHz @ -3 dB Gain Automatic gain control Display type High-resolution graphical LCD, 64 x 128 pixels, 53.0 mm x 27.0 mm with backlight and adjustable contrast Update rate 4 Hz or 8 Hz, user selectable, 24 Hz scan mode capture rate Thickness value display NORMAL view mode 5 Digit, 10.6 mm (0.4”) high B-SCAN view mode 5 Digit, 2.55 mm (0.1”) high Display of last reading Solid filled or hollow digits indicate coupled or uncoupled condition Setups 9 standard setups for probes Alarm settings Minimum and maximum alarms, range of 0.25 mm to 508 mm, 0. (0.010” to 20.00”) reading alternates between solid and hollow when alarms are enabled and violated Power requirements 2 “AA” size batteries Battery life/ operating time Approximately 60 hours Instrument shut-off Selectable ALWAYS ON or AUTO OFF after 5, 10, 15, 30 minutes of inactivity Language Selectable English, German, French, Spanish, Italian, Russian, Japanese and Chinese I/O connectors Transducer Dual Lemo 00 (coax) Mini-USB Mini USB to PC Temperature Operating -10°C to +50°C (+10°F to +120°F) Storage -20°C to +60°C (-10°F to +140°F) Size 138 mm x 32 mm x 75 mm Shock IEC 68-2-27 Ea, as per Mil Std 810C Method 516.2 Procedure I with a 15g 11ms impulse half sinusoidal wave applied 6 times per axis Sealing IEC529 / IP54, dust proof/dripping water proof as per IEC 529 specifications for IP54 classification